공급 업체와 통신? 공급 업체
Linda Yang Ms. Linda Yang
나는 당신을 위해 무엇을 할 수 있습니까?
공급 업체에 문의하십시오

Changchun New Industries Optoelectronics Technology Co., Ltd.

제품 리스트원자 램프펄스 레이저355nm Q-swiched Pluse DPSS UV 레이저
355nm Q-swiched Pluse DPSS UV 레이저
355nm Q-swiched Pluse DPSS UV 레이저
355nm Q-swiched Pluse DPSS UV 레이저
  • 355nm Q-swiched Pluse DPSS UV 레이저
  • 355nm Q-swiched Pluse DPSS UV 레이저
  • 355nm Q-swiched Pluse DPSS UV 레이저

355nm Q-swiched Pluse DPSS UV 레이저

    지불 유형: T/T,Western Union
    Incoterm: FOB
    최소 주문량: 1 Bag/Bags
    배송 시간: 20 일

기본 정보

모형: MPL-F/N/W-355

Transverse Mode: Near TEM00

Operating Mode: Frequency Conversion Of Q-switched Pulsed Laser

Warm-up Time (minutes): <10

Warranty Period: 1 Year

Central Wavelength (nm): 355±1

Output Average Power (mW): 1~2000

Single Pulse Energy (µJ): ~1.3,~5,~7

Ave Power Stability (over 4 Hours): <5%, <10%,<3%

Additional Info

포장: 정적 프리 비닐 봉지 및 카톤, 보호 패킹

생산력: 500

상표: CNI

수송: Air

원산지: 중국 (본토)

공급 능력: 500

인증 : ISO9001 FDA CE Rohs

HS 코드: 9013200099

포트: Beijing,Shenzhen,Xiangggang

제품 설명

상품 설명

355nm 다이오드 펌핑 솔리드 스테이트 (DPSS) 레이저는 1064nm에서 Nd : YAG 레이저 재료의 네 번째 고조파입니다. CW DPSS 266 nm에서 방출하는 레이저. 이 깊은 자외선 레이저는 UV 경화, 마이크로 일렉트로닉스, CD 조각, 레이저 의학 치료, 과학 실험 등에 널리 사용되는 초소형, 긴 수명, 비용 효과 및 간편한 작동과 같은 유용한 기능을 갖추고 있습니다 .

사양 1 :

Model MPL-F-355
Central wavelength (nm)
355±1
Output average power (mW)
1-100
Transverse mode
Near TEM00
Operating mode
Frequency conversion of Q-switched pulsed laser
Single pulse energy (µJ)
0.1-15
Pulse duration (ns)
~5                                                                                    
Peak power(W)
20-3000
Rep. rate (kHz)
FIXED             
Setting up one fixed rep. rate internal between 1kHz-4kHz with stable pulse energy, pulse duration and pulse period
EXT TRIG
1kHz-4kHz by external trigger with stable pulse energy, pulse duration and pulse period
QCW
QCW state with one rep. rate between5kHz-10kHz. 
Average power (mW)
Average power (mW) = Single pulse energy (µJ) * Rep. rate (kHz)
Ave power stability (over 4 hours)
<5%, <10%
Beam divergence, full angle (mrad)
<1.5
Beam diameter at the aperture (mm)
~2.0
Polarization ratio
>100:1
Pointing stability after warm-up (mrad)
<0.05
Warm-up time(minutes)
<10
Beam height from base plate (mm)
45
Operating temperature (℃)
10-35
Spectral purity
>99%
Power supply (90-264VAC)
PSI-H-FDA
Expected lifetime (hours)
5000
Warranty period
1 YEAR
Remarks
Please Note: because of the Walk-off effect of Nonlinear crystals, the beam quality of UV laser is not so good as that of 1064/532nm laser.

사양 2 :

Model MPL-N-355
Central wavelength (nm)
355±1
Output average power (mW)
1-800
Transverse mode
Near TEM00
Operating mode
Frequency conversion of Q-switched pulsed laser
Single pulse energy (µJ)
0.1-90
Pulse duration (ns)
~1.3,~7                                                                                  
Peak power(W)
80-13000
Rep. rate (kHz)
FIXED             
Setting up one fixed rep. rate internal between 1kHz-4kHz with stable pulse energy, pulse duration and pulse period
EXT TRIG
1kHz-4kHz by external trigger with stable pulse energy, pulse duration and pulse period
QCW
QCW state with one rep. rate between5kHz-10kHz. 
Average power (mW)
Average power (mW) = Single pulse energy (µJ) * Rep. rate (kHz)
Ave power stability (over 4 hours)
<3%, <5%
Warm-up time(minutes)
<10
Beam height from base plate (mm)
70
Operating temperature (℃)
10-35
Cooling system
Air
Power supply (90-264VAC)
PSI-N-LED/PSU-N-FDA
Expected lifetime (hours)
5000
Warranty period
1 YEAR
Remarks
Please Note: because of the Walk-off effect of Nonlinear crystals, the beam quality of UV laser is not so good as that of 1064/532nm laser.

사양 3 :

Model MPL-W-355
Central wavelength (nm)
355±1
Output average power (mW)
400-2000
Transverse mode
Near TEM00
Operating mode
Passively Q-switched 
Single pulse energy (µJ)
25-80
Pulse duration (ns)
~5                                                                                    
Peak power(W)
5-16
Rep. rate (kHz)
FIXED             
Setting up one fixed rep. rate internal between 1kHz-4kHz with stable pulse energy, pulse duration and pulse period
EXT TRIG
1kHz-4kHz by external trigger with stable pulse energy, pulse duration and pulse period
QCW
QCW state with one rep. rate between15kHz-25kHz. 
Average power (mW)
Average power (mW) = Single pulse energy (µJ) * Rep. rate (kHz)
Ave power stability (over 4 hours)
<3%, <5%
Beam divergence, full angle (mrad)
<2.0
Beam diameter at the aperture (mm)
~2.0
Warm-up time(minutes)
<10
Beam height from base plate (mm)
93.5
Operating temperature (℃)
10-35
Power supply (90-264VAC)
PSI-W-LED/PSU-W-FDA
Expected lifetime (hours)
8000
Warranty period
1 YEAR
Remarks
Please Note: because of the Walk-off effect of Nonlinear crystals, the beam quality of UV laser is not so good as that of 1064/532nm laser.

치수

MPL-F-355 PSU-H-FDA
DPSS UV Laser
DPSS UV Laser

MPL-N-355 PSU-N-LED PSU-N-FDA
DPSS UV Laser
DPSS UV Laser
DPSS UV Laser

MPL-W-355 PSU-W-LED PSU-W-FDA
DPSS UV Laser
DPSS UV Laser
DPSS UV Laser

인증
DPSS UV Laser
회사 정보

Changchun New Industries (CNI)는 중국 장춘 (Changchun)에 위치한 1996 년에 설립되었으며 반도체 및 다이오드 레이저 시스템의 선도적 인 제조업체입니다. 당사의 제품에는 녹색 레이저, 청색 레이저, 황색 레이저, 적색 레이저, RGB 레이저, 적외선 레이저, 자외선 레이저, 단일 종 방향 모드 레이저 및 Q 스위치 레이저 시스템이 포함됩니다. CNI 레이저는 OEM, 과학, 산업 및 계장 용으로 특별히 설계된 고성능, 저비용 및 우수한 레이저 빔 품질을 특징으로합니다. 또한, CNI 레이저는 ISO-9001, FDA, CE 및 JQA 인증을 받았습니다.

DPSS UV Laser

포장 및 배달
DPSS UV Laser
고객 방문
DPSS UV Laser
전시회

DPSS UV Laser

자주하는 질문

1. 배송은 어떻게됩니까?

TNT UPS 페덱스 DHL

2. 보증은 어떻게됩니까?

1 년간

3. 지불 방법?

웨스턴 유니온


제품 디렉토리 : 원자 램프 > 펄스 레이저

이 업체에게 이메일로 보내기
  • Linda YangMs. Linda Yang
  • 귀하의 메시지 20-8000 자 사이 여야합니다

Linda Yang

Ms. Linda Yang

SEND INQUIRY

  • Tell:

    86-0431-87025016

  • Fax:

    86-0431-87020258

  • E-mail:

    trade@cnilaser.com